Instructions for the installer
41
7.5 Regulation of primary air
Referred to distance “A” in mm.
60 cm hobs with separable control panel.
Burner
G20
20 mbar
G30/G31
28/37 mbar
Auxiliary (1) 3.0 4.0
Semirapid r (2) 1.0 2.0
Semirapid l (3) 1.0 2.0
Rapid large (4) 1.0 3.5
Ultrarapid (5) 1.0 5.0
90 cm hobs with separable control panel.
Burner
G20 G30/G31
20 mbar 28/37 mbar
Auxiliary (1) 2.5 3.0
Semirapid (2) 1.0 2.0
Rapid (3) 1.5 1.5
Fish burner (4) 0.5 8.0
Ultrarapid (5) 1.5 3.0
60 cm hob with built-in control panel.
Burner
G20 G30/G31
20 mbar 28/37 mbar
Auxiliary (1) 3.0 4.0
Semirapid r (2) 1.0 2.0
Semirapid l (3) 1.0 2.0
Rapid medio (4) 1.5 3.5
Ultrarapid (5) 1.0 4.0
To identify the burners on your hob, refer to the drawings in point “8.3/8.4 Arrangement of
burners on hob “